Building Designer - General Update
This Service pack enhances the following issues
Building Designer
A program instability which could occur when panning and zooming in the 2D view when arched grid lines exist.
On some computers and operating systems and depending on access privileges the NHF loadcase titles were being displayed as blank.
Reports - Beam End Forces : Max Min\Forces - when only one combination is selected - the section size which is reported below the beam reference was being omitted.
Reports - Brace Forces : Max\Min Forces - when only one combination is selected - the section size which is reported below the beam reference was being omitted.
Reports - Splice load report has been enhanced to include the component of eccentricity moment in the major and minor axes for General Columns.
The RHS, SHS and CHS orderfiles have been updated, because the automatic design of elements which allow these profiles would not select sections whose size ended in .0
Composite Beam Design - Concrete Decks when the PNA falls within the beam web, the program reported an infinite number for the calculaton of Moment Capacity for rolled and plated beams
Composite Beam Design - a crash occurred when combinations had been included for SLS design, but not included ULS design.
Finally, a number of tolerance issues have been addressed related to load decomposition and model generation and validation.
Moment Connection
A program instability which occurred when editing the bolt gauge.
Bolt lever arms were not being updated when section size of beam was changed.
Splice Connection
Check 3 Flange cover plate bolt group - When both internal and external flange plates are defined, the program was calculating the reduction factor incorrectly and also not taking account of the number of flange plates when calculating the bolt shear capacity ratio.
We have also included a refinement to the design model when a non bearing splice has both external and internal flange cover plates. So, Check 3 bearing on the flange cover plates - we now check both external and internal plate thicknesses, and the flange design force is shared 50:50 between them. However, to ensure that the external and internal plates are reasonably proportioned there are some amendments to Check 1 'Recommended detailing practice'.
Check 5 - Web cover plate group - Status of design check correct, but incorrect values were being displayed in the report for
Bearing capacity of bolt top pair
Bearing capacity of column web bolts
Bearing capacity ratio of column web
Simple Connection
Fin Plate connection, the horizontal bolt pitch gb was being incorrectly shown on the 2D view. This view is also used to draw the picture in the report.
Column Base Connection
Rib stiffeners - if the stiffener failed the weld design check, changing the stiffener weld leg length had no affect.